1 product guide ( utz-sc0293_0 ) 2011/10/11 ld receptacle module (ultra violet type) NUU205E engineering sample specifications ?opticalfiberoutputpower:150mw ?ferruletype:sc absolute maximum ratings item symbol absolute maximum ratings unit opticalfiberoutputpower* po 180 mw allowablereversecurrent ir(ld) 85 ma pdreversevoltage vr(pd) 5 v storagetemperature tstg 40~85 c operatingcasetemperature tc 20~30 c *corediameter=40 m,na=0.20,fiberlength=1.0m initial electrical/optical characteristics (tc=25 c) item symbol test condition min typ. max unit opticalfiberoutputpower* po cw 150 mw peakwavelength p po=150mw 370 375 380 nm thresholdcurrent* ith cw 200 260 ma operatingcurrent* iop po=150mw 390 480 ma slopeefficiency* cw 0.6 0.9 1.7 w/a operatingvoltage* vop po=150mw 4.5 5.0 v beamdivergence fullangle(1/e 2 )* po=150mw 11 15 deg. monitorcurrent** im po=150mw 1 ma *corediameter=40 m,na=0.20,fiberlength=1.0m **monitorcurrentisshorttimepowerreferencepu rposeonly.notguaranteedforaccuracy. all figures in this specification are measured by n ichia's method and may contain measurement deviatio ns. the above specifications are for reference purpose only and subjected to change without prior notice. outline dimension nichia corporation http://www.nichia.co.jp headquarters 491 oka, kaminaka-cho, anan-shi, tokushima 774-8601 , japan phone: +81-884-22-2311 fax: +81-884-21-0148 contact tokyo sales office 13f tamachi center building 34-7, shiba 5-chome, mi nato-ku, tokyo 108-0014, japan phone: +81-3-3456-3108 fax: +81-3-5440-7330 unit (mm) 4.4 0.1 7.6 0.2 0.2 0.15 11 0.1 9.45 0.2 1.55 0.1 NUU205E 000001 1.8 15.6max 8max serial number 1 2 3 6.5 1.0 2.0 0.2 3- 0.45 0.1 7max 7.0 0.2 4 4.4 0.1 7.6 0.2 0.2 0.15 11 0.1 9.45 0.2 1.55 0.1 NUU205E 000001 1.8 15.6max 8max serial number 1 2 3 6.5 1.0 2.0 0.2 3- 0.45 0.1 7max 7.0 0.2 4 1. ld anode 2. ld cathode 3. pd cathode 4. pd anode pin connection 12 ld 4 pd 3 (flange) protection device this model has a protection device built in as a protection circuit against static electricity. 1. ld anode 2. ld cathode 3. pd cathode 4. pd anode pin connection 12 ld 4 pd 3 (flange) protection device this model has a protection device built in as a protection circuit against static electricity.
2 product guide ( utz-sc0293_0 ) 2011/10/11 cautions (1) safety of laser light laser light can damage the human eyes and skin. do not expose the eye or skintoanylaserlightdirectlyand/orthroughopt icallens.whenhandlingtheld receptaclemodules,wearappropriatesafetyglasses topreventlaserlight,even any reflections from entering to the eye. focused l aser beam through optical instrumentswillincreasethechanceofeyehazard. theseldreceptaclemodulesareclassifiedin class 3b of the iec60825-1 and 21 cfr part 1040.10 safety standards . it is absolutely necessary to take overall safety measures against user's modules, equ ipment and systems into whichnichialdreceptaclemodulesareincorporated and/orintegrated. (2) operating method the ld receptacle module shall change its forward v oltage requirement and optical output power accordi ng to temperature change. also, the ld receptacle module will require more operation current to maintain sam e output power as it degrades. in order to maintain output p ower, use of apc (automatic power control) is recom mended, whichusemonitorfeedbacktoadjusttheoperation current. confirm that electrical spike current generated by switching on and off does not exceed the maximum op erating current level specified herein above as absolute ma x rating. also, employ appropriate countermeasures to reduce chatteringand/orovershootinginthecircuit. (3) static electricity static electricity or electrical surges will reduce and degrade the reliability of the ld receptacle m odules. it is recommendedtouseawriststraporantielectrosta ticglovewhenhandlingtheproduct. (4) absolute maximum rating active layer of ld receptacle modules shall have hi gh current density and generate high electric field during its operation.inordertopreventexcessivedamage,th eldreceptaclemodulemustbeoperatedstrictlybe lowabsolute maxrating. (5) others nichialdreceptaclemodulesdescribedinthisbroc hureareintendedtobeusedforordinaryelectroni cequipment (suchasofficeequipment,communicationsequipment ,measurementinstrumentsandhouseholdappliances) .consult nichias sales staff in advance for information on the applications in which exceptional quality and r eliability are required,particularlywhenthefailureormalfunct ionoftheldreceptaclemodulesmaydirectlyjeopa rdizelifeor health (such as for airplanes, aerospace, submersib le repeaters, nuclear reactor control systems, auto mobiles, traffic controlequipment,lifesupportsystemsandsafety devices). nichiaprohibitpurchaserfromreverseengineering, disassembling,ortakinganyotherstepstoderive thestructureor designoftheldreceptaclemodule. the appearance and specifications of the product ma y be modified for improvement without notice. the f ormal specificationsmustbeexchangedandsignedbyboth partiesbeforelargevolumepurchasebegins.
|